Unit Price:$0
Ext Price:$0



FLC10-200H is an STMicroelectronics capacitance-discharge ignition device integrating a thyristor, zener threshold element, reverse-conduction diode and 2 kΩ resistor in an IPAK through-hole package.
Selection details are based on the ST FLC10 datasheet, DocID5202 Rev 8. Check the complete design against the controlled datasheet.
The FLC10 series is designed for high-power capacitance-discharge ignition. In a representative circuit, a storage capacitor charges from a rectified AC supply; when its voltage reaches the integrated zener threshold, the thyristor fires and transfers energy through an ignition-transformer primary. The integrated diode provides a reverse-current path during the discharge cycle.
Combines switching, threshold, reverse-current and resistive elements in one device.
Rated for 240 A repetitive surge peak current at a 10 µs pulse under the datasheet conditions.
Specified operating ambient range extends to +120 °C.
The H ordering suffix identifies the through-hole IPAK package.
The 200 code denotes 200 V stand-off voltage.
The zener initiates thyristor firing as the storage capacitor reaches breakover.
Critical on-state current rise rate is rated at 200 A/µs.
ST lists FLC10-200H as the IPAK, tube-delivered order code.
ST's exact order-code table identifies FLC10-200H as IPAK. The customer package field also lists TO-251-3 Short Leads and TO-251AA as package aliases; use the manufacturer IPAK drawing and dimensions for footprint and mechanical verification.

The registered IPAK JPG is currently missing from the local package library; this image path is reserved for the verified file and must not be treated as a confirmed illustration.
The ST functional diagram groups pins 1 and 3 as one circuit connection and pin 2 with the tab as the other connection.
Common circuit node; ST explicitly requires these pins to be shorted together in the application layout.
Opposite power terminal in the ST functional diagram; include the tab connection in the PCB layout.
Confirm orientation and terminal identification against the ST IPAK package drawing before routing or substitution.
| Manufacturer order code | FLC10-200H |
|---|---|
| Function | Integrated capacitance-discharge fire lighter circuit |
| Stand-off voltage class | 200 V |
| Breakover voltage, VBO | 200 V min / 225 V typ / 250 V max at IBO, Tj = 25 °C |
| Breakover current, IBO | 0.5 mA max at VBO, Tj = 25 °C |
| Repetitive surge peak current | 240 A for a 10 µs pulse, −30 °C ≤ Tamb ≤ +120 °C |
| Critical on-state current rise rate | 200 A/µs, −30 °C ≤ Tamb ≤ +120 °C |
| Thyristor on-state voltage, VT | 1.7 V max at IT = 2 A, pulse ≤ 500 µs, Tj = 25 °C |
| Diode forward voltage, VF | 1.7 V max at IF = 2 A, pulse ≤ 500 µs, Tj = 25 °C |
| Internal resistor | 2 kΩ in the functional diagram |
| Operating ambient range | −30 °C to +120 °C |
| Junction-to-ambient thermal resistance | 100 °C/W for IPAK |
| Package and delivery | IPAK, tube |
Electrical figures are datasheet limits or typical values only at the stated test conditions; do not apply them as unconditional circuit ratings.
ST also lists FLC10-200B in the same FLC10 family, but it uses DPAK rather than IPAK and has a different mounting footprint. It is a design-comparison candidate, not a drop-in mechanical replacement. Compare the exact order code, lead/tab mapping, surge waveform, thermal path, operating temperature and applicable approvals before redesign. No unverified internal product link is provided.
STMicroelectronics specifies FLC10-200H in the FLC10 fire lighter circuit datasheet (DocID5202 Rev 8, June 2014). The H suffix denotes IPAK; the related B suffix denotes DPAK. Consult the latest ST-controlled documentation and product status before new design use.
Capacitance-discharge spark ignition stages.
High-voltage transformer drive in a validated ignition circuit.
Compact, integrated pulse-switching implementation.
Designs requiring controlled capacitor discharge and reverse-current conduction.
Verify the full order code, ST marking, IPAK body and lead geometry, and traceability against the manufacturer's controlled documentation. Package drawings and markings should be checked on received material; do not infer authenticity from an illustration alone.
ST's ordering scheme identifies H as the IPAK package for FLC10-200H.
No. The B code is DPAK, so footprint and thermal mounting differ; electrical and safety conditions also require review.
ST's functional diagram explicitly says to short pins 1 and 3 together in the application layout.
Capacitance-discharge ignition circuits can produce hazardous mains and high-voltage pulses. Validate isolation, spark energy, repetition rate, component derating, PCB geometry and thermal behavior in the final product. The package illustration is unavailable pending a verified IPAK JPG; do not release this detail for publication until that resource is checked.
The following parts include "FLC10-200H" in Silicon Labs FLC10-200H.