Unit Price:$0
Ext Price:$0



CAP009DG-TL is a Power Integrations CAPZero automatic X-capacitor discharge IC for AC-input equipment. The CAP009 selection is the 825-V grade for up to 5 microfarads of total X capacitance with the specified external discharge-resistor network. DG identifies the green SO-8 package; TL identifies tape-and-reel delivery.
Mains-connected designs require a complete safety, surge and discharge-time review; this summary is not a substitute for the manufacturer's application circuit.
When AC input is present, CAPZero blocks current through the X-capacitor safety-discharge resistors to reduce standby loss. When AC is removed, the device reconnects the resistor path so the X capacitor discharges. The two-terminal function is self-supplied and does not require a separate bias rail or ground connection.
Disconnects the discharge resistors during normal AC operation to avoid continuous resistive loss.
Restores the resistor path after input removal to discharge the X capacitor.
Requires no separate control input or external bias supply.
Supports larger X capacitors while maintaining a controlled discharge network.
825-V breakdown grade with a manufacturer table entry for 5-microfarad maximum total X capacitance.
The selection table specifies 150 kilohms total series resistance (the minimum permitted for this selection) for CAP009.
The SO-8 pin arrangement maintains more than 4 mm creepage across the package and PCB when laid out as specified.
Can be applied before or after the system input fuse, subject to the manufacturer's safety guidance.
The manufacturer's D package is plastic SO-8, and G denotes a halogen-free, RoHS-compliant material option. TL specifies tape and reel. LCDChip registers 8-SOIC (0.154", 3.90 mm width), consistent with the manufacturer's 3.90-mm body drawing.

This generic JPG does not show CAPZero pin connections.
The data sheet identifies D1 on pins 2 and 3 and D2 on pins 6 and 7; pins 1, 4, 5 and 8 are NC in the package diagram. The manufacturer recommends grouping pins 1-4 and pins 5-8 on the PCB to support the specified creepage arrangement. Follow the controlled application layout rather than treating the generic package JPG as a pin diagram.
| Product family | CAPZero automatic X-capacitor discharge IC |
|---|---|
| Manufacturer | Power Integrations |
| Exact order code | CAP009DG-TL |
| Breakdown grade | 825 V |
| Maximum total X capacitance | 5 microfarads, per selection table |
| Total series resistance selection | 150 kilohms, R1 + R2; lowest permitted resistor value in the selection table |
| External bias | Not required; self-supplied |
| Functional terminals | D1 and D2 |
| Package | D plastic SO-8; registry 8-SOIC |
| Package material | G green / halogen-free / RoHS compliant |
| Delivery form | TL tape and reel |
For CAP009, the table footnote identifies 150 kilohms as the lowest usable resistor value. Use the complete data sheet for tolerances, surge limits and compliance testing.
Another CAPZero order code may differ in breakdown grade, supported X capacitance or nominal resistor value. A CAP019 1000-V option, for example, is not a drop-in approval without reviewing MOV location, surge conditions and the discharge network. Validate the end-product safety test and packaging requirement. No unverified internal alternative link is asserted.
Power Integrations documents CAP009DG in the CAPZero Family data sheet, revision H. Its component-selection table specifies the CAP009 electrical selection, and the part-ordering section defines D, G and TL. The manufacturer also provides application considerations for MOV placement, surge measurement and X-capacitor discharge.
Reduce discharge-resistor loss in input EMI filters.
Support low-standby-power designs with X-capacitor discharge requirements.
Maintain a controlled discharge path without steady resistor loss.
Allow X-capacitor selection within the manufacturer's CAP009 table limits.
Verify the complete CAP009DG-TL order code, reel and lot labels, package marking and traceability. Incoming and end-product tests should confirm the expected circuit behavior, surge withstand and discharge time; exterior marking alone cannot establish mains-safety compliance.
No. CAPZero is self-supplied as a two-terminal functional device.
It identifies tape-and-reel delivery of the SO-8 device.
No. MOV location and measured differential surge determine the required voltage grade.
No. External discharge resistors remain necessary and must be selected using the manufacturer's table.
This device connects to a mains-related safety circuit. Use the current Power Integrations data sheet, package drawing and applicable safety standards for schematic, PCB creepage, fuse/MOV placement, fault analysis, surge testing and discharge-time verification. Only qualified engineers should approve the final implementation.
The following parts include "CAP009DG-TL" in Silicon Labs CAP009DG-TL.
The following parts are popular search parts in Test and Measurement.