Miniature Circuit Breaker (MCB) - Mitsubishi (WS-V series - Miniature Circuit Breakers (MCBs) (IEC)) - 1-pole (1P) - Rated current 3A - I (Magnetic only)-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Screw-clamp connection
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-C (economy class)) - 3-poles (3P) - Rated current 15A - Short circuit breaking capacity (Icu) 1.5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars...
Miniature Circuit Breaker (MCB) - Mitsubishi (WS-V series - Miniature Circuit Breakers (MCBs) (IEC)) - 1-pole (1P) - Rated current 5A - I (Magnetic only)-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Screw-clamp connection
Miniature Circuit Breaker (MCB) - Mitsubishi (WS-V series - Miniature Circuit Breakers (MCBs) (IEC)) - 1-pole (1P) - Rated current 7A - I (Magnetic only)-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Screw-clamp connection
Miniature Circuit Breaker (MCB) protector - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 1-pole (1P) - Rated current 0.1A - M-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circuit current rating 2.5kA (250Va...
Miniature Circuit Breaker (MCB) protector - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 1-pole (1P) - Rated current 0.3A - M-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circuit current rating 2.5kA (250Va...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-C (economy class)) - 2-poles (2P) - Rated current 15A - Short circuit breaking capacity (Icu) 5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars c...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-C (economy class)) - 2-poles (2P) - Rated current 16A - Short circuit breaking capacity (Icu) 5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars c...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-C (economy class)) - 2-poles (2P) - Rated current 20A - Short circuit breaking capacity (Icu) 5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars c...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-C (economy class)) - 2-poles (2P) - Rated current 25A - Short circuit breaking capacity (Icu) 5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars c...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-C (economy class)) - 2-poles (2P) - Rated current 30A - Short circuit breaking capacity (Icu) 5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars c...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-C (economy class)) - 2-poles (2P) - Rated current 32A - Short circuit breaking capacity (Icu) 5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars c...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-C (economy class)) - 2-poles (2P) - Rated current 40A - Short circuit breaking capacity (Icu) 5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars c...
Thermal overload O/L protection relay (TOR) with 3 heating elements (overload + phase failure protection) - Mitsubishi Electric (TH-T series) - 3-poles (3P) - 5.2A...8A trip current setting range - with 1NO+1NC aux. contacts - Screw-clamp connections w...
Thermal overload O/L protection relay (TOR) with 3 heating elements (overload + phase failure protection) - Mitsubishi Electric (TH-T series) - 3-poles (3P) - 7A...11A trip current setting range - with 1NO+1NC aux. contacts - Screw-clamp connections wi...
Thermal overload O/L protection relay (TOR) with 3 heating elements (overload + phase failure protection) - Mitsubishi Electric (TH-N series) - 3-poles (3P) - 140A...220A trip current setting range - with 1NO+1NC aux. contacts - Mech. lugs connections ...
Thermal overload O/L protection relay (TOR) with 3 heating elements (overload + phase failure protection) - Mitsubishi Electric (TH-N series) - 3-poles (3P) - 170A...250A trip current setting range - with 1NO+1NC aux. contacts - Mech. lugs connections ...
Thermal overload O/L protection relay (TOR) with 3 heating elements (overload + phase failure protection) - Mitsubishi Electric (TH-N series) - 3-poles (3P) - 85A...125A trip current setting range - with 1NO+1NC aux. contacts - Mech. lugs connections -...
Thermal overload O/L protection relay (TOR) with 3 heating elements (overload + phase failure protection) - Mitsubishi Electric (TH-N series) - 3-poles (3P) - 100A...150A trip current setting range - with 1NO+1NC aux. contacts - Mech. lugs connections ...
Thermal overload O/L protection relay (TOR) with 3 heating elements (overload + phase failure protection) - Mitsubishi Electric (TH-N series) - 3-poles (3P) - 120A...180A trip current setting range - with 1NO+1NC aux. contacts - Mech. lugs connections ...