Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-C (economy class)) - 3-poles (3P) - Rated current 3A - Short circuit breaking capacity (Icu) 5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars co...
Replacement coil - Mitsubishi Electric - Control coil voltage 110Vac-120Vac (50Hz) / 115-120Vac(60Hz) - compatible with Def. Purpose D.C. cont. - equivalent to DU-A30-COILAC120V
Thermal overload O/L protection relay (TOR) with 3 heating elements (overload + phase failure protection) - Mitsubishi Electric (TH-N series) - 3-poles (3P) - 2.8A...4.4A trip current setting range - with 1NO+1NC aux. contacts - Screw-clamp connections...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-C (economy class)) - 3-poles (3P) - Rated current 4A - Short circuit breaking capacity (Icu) 5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars co...
Thermal overload O/L protection relay (TOR) with 3 heating elements (overload + phase failure protection) - Mitsubishi Electric (TH-N series) - 3-poles (3P) - 2.8A...4.4A trip current setting range - with 1NO+1NC aux. contacts - Screw-clamp connections...
Thermal overload O/L protection relay (TOR) with 3 heating elements (overload + phase failure protection) - Mitsubishi Electric (TH-N series) - 3-poles (3P) - 18A...26A trip current setting range - with 1NO+1NC aux. contacts - Mech. lugs connections - ...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-C (economy class)) - 3-poles (3P) - Rated current 5A - Short circuit breaking capacity (Icu) 5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars co...
Thermal overload O/L protection relay (TOR) with 3 heating elements (overload + phase failure protection) - Mitsubishi Electric (TH-N series) - 3-poles (3P) - 4.0A...6.0A trip current setting range - with 1NO+1NC aux. contacts - Screw-clamp connections...
Thermal overload O/L protection relay (TOR) with 3 heating elements (overload + phase failure protection) - without cooling fin - Mitsubishi Electric (TH-N series) - 3-poles (3P) - 12A...18A trip current setting range - with 1NO+1NC aux. contacts - Scr...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-C (economy class)) - 3-poles (3P) - Rated current 6A - Short circuit breaking capacity (Icu) 5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars co...
Thermal overload O/L protection relay (TOR) with 3 heating elements (overload + phase failure protection) - Mitsubishi Electric (TH-N series) - 3-poles (3P) - 12A...18A trip current setting range - with 1NO+1NC aux. contacts - Mech. lugs connections - ...
Thermal overload O/L protection relay (TOR) with 3 heating elements (overload + phase failure protection) - Mitsubishi Electric (TH-N series) - 3-poles (3P) - 5.2A...8.0A trip current setting range - with 1NO+1NC aux. contacts - Screw-clamp connections...
Thermal-Magnetic Motor Protection Circuit Breaker (MPCB) / Manual Mot. Protector Starter - Mitsubishi (WS-V series - MMP-T Motor Circuit Breakers) - 3-poles (3P) - Rated current 13A - Short circuit breaking capacity (Icu) 100kA (400Vac; IEC60947) - The...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-C (economy class)) - 3-poles (3P) - Rated current 10A - Short circuit breaking capacity (Icu) 5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars c...
Thermal overload O/L protection relay (TOR) - Mitsubishi Electric (TH-T series) - 3-poles (3P) - 34A...50A trip current setting range - with 1NO+1NC aux. contacts - Screw-clamp connections with finger protection - equivalent to TH-T6542A Equivalent to ...
Thermal overload O/L protection relay (TOR) with 3 heating elements (overload + phase failure protection) - Mitsubishi Electric (TH-N series) - 3-poles (3P) - 7.0A...11A trip current setting range - with 1NO+1NC aux. contacts - Screw-clamp connections ...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-C (economy class)) - 3-poles (3P) - Rated current 15A - Short circuit breaking capacity (Icu) 5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars c...
Thermal-Magnetic Motor Protection Circuit Breaker (MPCB) / Manual Mot. Protector Starter - Mitsubishi (WS-V series - MMP-T Motor Circuit Breakers) - 3-poles (3P) - Rated current 18A - Short circuit breaking capacity (Icu) 50kA (400Vac; IEC60947) - Ther...
Thermal overload O/L protection relay (TOR) with 3 heating elements (overload + phase failure protection) - Mitsubishi Electric (TH-T series) - 3-poles (3P) - 12A...18A trip current setting range - with 1NO+1NC aux. contacts - Screw-clamp connections w...
Thermal-Magnetic Motor Protection Circuit Breaker (MPCB) / Manual Mot. Protector Starter - Mitsubishi (WS-V series - MMP-T Motor Circuit Breakers) - 3-poles (3P) - Rated current 25A - Short circuit breaking capacity (Icu) 50kA (400Vac; IEC60947) - Ther...