Shunt trip release coil - for right pole - Mitsubishi - Coil control voltage 100Vdc - compatible with frame size 30A-250A (2-poles; 3-poles and 4-poles)
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-S (standard class)) - 2-poles (2P) - Rated current 32A - Short circuit breaking capacity (Icu) 7.5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bar...
Shunt trip release coil with vertical lead-wire term. block - for right pole; 2-poles; 3-poles - Mitsubishi - Coil control voltage 380Vac-550Vac - compatible with frame size 30A-250A
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (OEM MXA series - S type) - 3-poles (3P) - Rated current 32A - Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars connection ...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-S (standard class)) - 2-poles (2P) - Rated current 125A - Short circuit breaking capacity (Icu) 36kA (400Vac; IEC60947) - Thermal-Magnetic (adjustable) trip unit - Front lugs o...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-S (standard class)) - 2-poles (2P) - Rated current 40A - Short circuit breaking capacity (Icu) 7.5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bar...
Undervoltage trip release coil - reset type - Mitsubishi - Coil control voltage 100Vac-120Vac - compatible with frame size 30A-250A
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (OEM MXA series - S type) - 3-poles (3P) - Rated current 40A - Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars connection ...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (OEM MXA series - S type) - 3-poles (3P) - Rated current 50A - Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars connection ...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (OEM MXA series - S type) - 3-poles (3P) - Rated current 250A - Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars connection...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (OEM MXA series - S type) - 3-poles (3P) - Rated current 60A - Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars connection ...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (OEM MXA series - S type) - 4-poles (4P) - Rated current 175A - Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars connection...
Shunt trip release coil - for right and left pole - Mitsubishi - Coil control voltage 100Vac-240Vac - compatible with frame size 30A-250A
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (OEM MXA series - S type) - 4-poles (4P) - Rated current 200A - Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars connection...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (OEM MXA series - S type) - 3-poles (3P) - Rated current 63A - Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars connection ...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (OEM MXA series - S type) - 4-poles (4P) - Rated current 225A - Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars connection...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (OEM MXA series - S type) - 3-poles (3P) - Rated current 75A - Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars connection ...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (OEM MXA series - S type) - 4-poles (4P) - Rated current 250A - Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars connection...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (OEM MXA series - S type) - 3-poles (3P) - Rated current 80A - Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars connection ...
Trip alarm auxiliary contact/switch block - standard type - for left pole - Mitsubishi - with SPDT (Single Pole Double Throw) NO/NC contacts - compatible with frame size 30A-250A (2-poles; 3-poles and 4-poles)