Miniature Circuit Breaker (MCB) protector - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 3-poles (3P) - Rated current 10A - MD-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circuit current rating 2.5kA (250V...
Miniature Circuit Breaker (MCB) protector with pre-installed alarm sw. - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 2-poles (2P) - Rated current 7A - S-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circuit...
Miniature Circuit Breaker (MCB) protector with pre-installed auxiliary sw. - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 3-poles (3P) - Rated current 3A - MD-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short ci...
Miniature Circuit Breaker (MCB) protector - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 3-poles (3P) - Rated current 15A - S-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circuit current rating 2.5kA (250Va...
Miniature Circuit Breaker (MCB) protector with pre-installed alarm sw. - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 3-poles (3P) - Rated current 10A - MD-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circu...
Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed auxiliary sw. + vertical lead-wire term. block - Mitsubishi (WS-V series - NF-S (standard class)) - 3-poles (3P) - Rated current 16A - Short circuit breaking capacity (Icu) 5kA (400Vac; IE...
Miniature Circuit Breaker (MCB) protector - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 3-poles (3P) - Rated current 1A - S-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circuit current rating 2.5kA (250Vac...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-S (standard class)) - 3-poles (3P) - Rated current 4A - Short circuit breaking capacity (Icu) 5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars c...
Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed auxiliary sw. + vertical lead-wire term. block - Mitsubishi (WS-V series - NF-S (standard class)) - 3-poles (3P) - Rated current 30A - Short circuit breaking capacity (Icu) 5kA (400Vac; IE...
Miniature Circuit Breaker (MCB) protector - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 3-poles (3P) - Rated current 15A - MD-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circuit current rating 2.5kA (250V...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-S (standard class)) - 3-poles (3P) - Rated current 20A - Short circuit breaking capacity (Icu) 7.5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bar...
Miniature Circuit Breaker (MCB) protector - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 3-poles (3P) - Rated current 20A - S-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circuit current rating 2.5kA (250Va...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-S (standard class)) - 3-poles (3P) - Rated current 5A - Short circuit breaking capacity (Icu) 5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars c...
Undervoltage trip release coil with vertical lead-wire term. block - reset type - for right and left pole - Mitsubishi - Coil control voltage 380Vac-480Vac - compatible with frame size 400A-630A; 800A (3-poles)
Miniature Circuit Breaker (MCB) protector - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 3-poles (3P) - Rated current 1A - MD-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circuit current rating 2.5kA (250Va...
Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed auxiliary sw. - Mitsubishi (WS-V series - NF-S (standard class)) - 2-poles (2P) - Rated current 6A - Short circuit breaking capacity (Icu) 5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed)...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-S (standard class)) - 3-poles (3P) - Rated current 6A - Short circuit breaking capacity (Icu) 5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bars c...
Moulded / Molded Case Circuit Breaker (MCCB) - Mitsubishi (WS-V series - NF-S (standard class)) - 3-poles (3P) - Rated current 25A - Short circuit breaking capacity (Icu) 7.5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed) trip unit - Front lugs or bar...
Miniature Circuit Breaker (MCB) protector - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 3-poles (3P) - Rated current 2A - S-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circuit current rating 2.5kA (250Vac...
Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed auxiliary sw. - Mitsubishi (WS-V series - NF-S (standard class)) - 3-poles (3P) - Rated current 10A - Short circuit breaking capacity (Icu) 5kA (400Vac; IEC60947) - Thermal-Magnetic (fixed...