Magnetic contactor - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Mitsubishi Electric (MS-N series) - 3-poles (3P) - Rated current 800A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 440kW (440Vac; AC-3; IEC) / 600HP (480Vac; 3-phase; ...
Magnetic contactor - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Mitsubishi Electric (MS-N series) - 3-poles (3P) - Rated current 800A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 440kW (440Vac; AC-3; IEC) / 600HP (480Vac; 3-phase; ...
Miniature Circuit Breaker (MCB) protector with pre-installed alarm sw. - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 2-poles (2P) - Rated current 15A - M-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circui...
Replacement coil - Mitsubishi Electric - Control coil voltage 200Vac-240Vac (50Hz/60Hz) (208Vac / 220Vac / 230Vac) - compatible with N600; N800 - equivalent to S-N600-COILAC200V Equivalent to S-N600-COILAC200V
Magnetic contactor - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Mitsubishi Electric (MS-N series) - 3-poles (3P) - Rated current 300A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 160kW (440Vac; AC-3; IEC) / 200HP (480Vac; 3-phase; ...
Replacement coil - Mitsubishi Electric - Control coil voltage 380Vac-440Vac (50Hz/60Hz) (400Vac / 415Vac) - compatible with N600; N800 - equivalent to S-N600-COILAC400V Equivalent to S-N600-COILAC400V
Miniature Circuit Breaker (MCB) protector with pre-installed alarm sw. - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 2-poles (2P) - Rated current 1A - M-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circuit...
Miniature Circuit Breaker (MCB) protector with pre-installed alarm sw. - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 2-poles (2P) - Rated current 20A - M-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circui...
Magnetic contactor - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Mitsubishi Electric (MS-N series) - 3-poles (3P) - Rated current 300A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 160kW (440Vac; AC-3; IEC) / 200HP (480Vac; 3-phase; ...
Miniature Circuit Breaker (MCB) protector with pre-installed alarm sw. - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 2-poles (2P) - Rated current 2A - M-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circuit...
Magnetic contactor - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Mitsubishi Electric (MS-N series) - 3-poles (3P) - Rated current 300A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 160kW (440Vac; AC-3; IEC) / 200HP (480Vac; 3-phase; ...
Miniature Circuit Breaker (MCB) protector with pre-installed alarm sw. - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 2-poles (2P) - Rated current 30A - M-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circui...
Compact magnetic contactor - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Mitsubishi Electric (MS-N series) - 3-poles (3P) - Rated current 32A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 15kW (440Vac; AC-3; IEC) - Control coil volta...
Miniature Circuit Breaker (MCB) protector with pre-installed alarm sw. - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 2-poles (2P) - Rated current 3A - M-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circuit...
Miniature Circuit Breaker (MCB) protector with pre-installed alarm sw. - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 2-poles (2P) - Rated current 7A - M-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circuit...
Miniature Circuit Breaker (MCB) protector with pre-installed alarm sw. - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 2-poles (2P) - Rated current 0.1A - MD-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circ...
Miniature Circuit Breaker (MCB) protector with pre-installed alarm sw. - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 2-poles (2P) - Rated current 0.25A - MD-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short cir...
Miniature Circuit Breaker (MCB) protector with pre-installed alarm sw. - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 2-poles (2P) - Rated current 5A - M-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circuit...
Miniature Circuit Breaker (MCB) protector with pre-installed alarm sw. - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 2-poles (2P) - Rated current 0.3A - MD-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circ...
Miniature Circuit Breaker (MCB) protector with pre-installed alarm sw. - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 2-poles (2P) - Rated current 0.5A - MD-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circ...