Magnetic contactor - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Mitsubishi Electric (MS-N series) - 3-poles (3P) - Rated current 85A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 45kW (440Vac; AC-3; IEC) / 50HP (480Vac; 3-phase; UL)...
Magnetic contactors reverser assembly - Reversing (REV) / FVR (Full-Voltage Reversing) - Mitsubishi Electric (MS-N series) - 2 x 3-poles (2 x 3P / 3NO poles) - Rated current 30A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 15kW (440Vac; AC-3...
#phasing-out - Magnetic contactors reverser assembly - Reversing (REV) / FVR (Full-Voltage Reversing) - Mitsubishi Electric (MS-N series) - 2 x 3-poles (2 x 3P / 3NO poles) - Rated current 30A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 15k...
Magnetic contactor - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Mitsubishi Electric (MS-N series) - 3-poles (3P) - Rated current 85A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 45kW (440Vac; AC-3; IEC) / 50HP (480Vac; 3-phase; UL)...
Miniature Circuit Breaker (MCB) protector - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 2-poles (2P) - Rated current 10A - S-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circuit current rating 2.5kA (250Va...
Magnetic contactor - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Mitsubishi Electric (MS-N series) - 3-poles (3P) - Rated current 85A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 45kW (440Vac; AC-3; IEC) / 50HP (480Vac; 3-phase; UL)...
Magnetic contactor - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Mitsubishi Electric (MS-N series) - 3-poles (3P) - Rated current 105A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 55kW (440Vac; AC-3; IEC) / 60HP (480Vac; 3-phase; UL...
#phasing-out - Magnetic contactors reverser assembly - Reversing (REV) / FVR (Full-Voltage Reversing) - Mitsubishi Electric (MS-N series) - 2 x 3-poles (2 x 3P / 3NO poles) - Rated current 30A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 15k...
Magnetic contactor - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Mitsubishi Electric (MS-N series) - 3-poles (3P) - Rated current 105A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 55kW (440Vac; AC-3; IEC) / 60HP (480Vac; 3-phase; UL...
#phasing-out - Magnetic contactors reverser assembly - Reversing (REV) / FVR (Full-Voltage Reversing) - Mitsubishi Electric (MS-N series) - 2 x 3-poles (2 x 3P / 3NO poles) - Rated current 30A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 15k...
Magnetic contactor - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Mitsubishi Electric (MS-N series) - 3-poles (3P) - Rated current 105A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 55kW (440Vac; AC-3; IEC) / 60HP (480Vac; 3-phase; UL...
Magnetic contactor - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Mitsubishi Electric (MS-N series) - 3-poles (3P) - Rated current 105A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 55kW (440Vac; AC-3; IEC) / 60HP (480Vac; 3-phase; UL...
Magnetic contactor - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Mitsubishi Electric (MS-N series) - 3-poles (3P) - Rated current 105A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 55kW (440Vac; AC-3; IEC) / 60HP (480Vac; 3-phase; UL...
Magnetic contactor - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Mitsubishi Electric (MS-N series) - 3-poles (3P) - Rated current 105A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 55kW (440Vac; AC-3; IEC) / 60HP (480Vac; 3-phase; UL...
Magnetic contactor - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Mitsubishi Electric (MS-N series) - 3-poles (3P) - Rated current 40A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 18.5kW (440Vac; AC-3; IEC) / 20HP (480Vac; 3-phase; U...
#phasing-out - Magnetic contactor - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Mitsubishi Electric (MS-N series) - 3-poles (3P) - Rated current 40A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 18.5kW (440Vac; AC-3; IEC) / 20HP (480...
Miniature Circuit Breaker (MCB) protector - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 2-poles (2P) - Rated current 15A - S-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circuit current rating 2.5kA (250Va...
Magnetic contactor - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Mitsubishi Electric (MS-N series) - 3-poles (3P) - Rated current 40A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 18.5kW (440Vac; AC-3; IEC) / 20HP (480Vac; 3-phase; U...
#phasing-out - Magnetic contactor - Direct On Line (DOL) / FVNR (Full-Voltage Non-Rv.) - Mitsubishi Electric (MS-N series) - 3-poles (3P) - Rated current 40A (380Vac / 400Vac / 415Vac / 440Vac; AC-3) - Rated power 18.5kW (440Vac; AC-3; IEC) / 20HP (480...
Miniature Circuit Breaker (MCB) protector - Mitsubishi (WS-V series - Circuit protectors (UL1077)) - 2-poles (2P) - Rated current 1A - S-curve - Short circuit breaking capacity (Icu) 2.5kA (230Vac; IEC60947) - Short circuit current rating 2.5kA (250Vac...